claim
---

Pepperl+Fuchs Blog

Mission Fieldbus—25 years of PROFIBUS & PROFINET International (PI)

Posted by Nicolas Poellmann on Fri, Nov 06, 2015

Interview with Long-Standing Member of the PNO Advisory Board, Juergen George about the Past, Present, and Future of Fieldbus Technology

PROFIBUS & PROFINET International (PI) celebrates its 25th birthday in 2015—an organization in which Juergen George from Pepperl+Fuchs was involved from the outset. Over the decades, he has influenced the definition of standards in fieldbus technology through various bodies, committees, and working groups. In celebration of PI's anniversary and George's retirement, we invited him to an interview: What does the future hold for PI? What will he remember most from his eventful career in service of "Mission Fieldbus"?

Read More

Topics: Ask an Expert, Fieldbus

Ask an Expert Industrial Sensors: Episode 13

Posted by John Appleson on Thu, Oct 29, 2015

This episode of Ask an Expert for industrial sensors examines and provides answers to interesting sensing questions we've received from customers just like you. We explore and answer these questions:

1. Is the NJ15+U4+W inductive proximity sensor waterproof?
2. How do you power the LED on the sensor NBB4-12GM50-A2-V1?
3. Is the NJ4-12GK-SN the right sensor for use with valve actuators?
4. Does the NMB1.5-8GM50-E2-C-FE-V1 inductive sensor have a pigtail cable version?

Read More

Topics: Inductive Sensors, Ask an Expert

Ask an Expert Industrial Sensors-Episode 12

Posted by John Appleson on Thu, Sep 10, 2015

This episode of Ask an Expert for industrial sensors examines and provides answers to interesting sensing questions we've received from customers just like you. We explore and answer these questions:

  1. How to configure the AS-Interface VAS-2A-K12 safety monitor with a SLC ASI master card for a SLC 5/03 CPU (Allen-Bradley)?
  2. Do you have cabling that can connect to an ML7 series photoelectric sensor at a distance?
  3. How to program the UB1000-18GM75-I-V15 ultrasonic sensor?
  4. Can the inductive sensor NCB10-30GM40-N0-5M be used in offshore or marine applications?
  5. Will the NBN40-L2-E2-V1 inductive sensor be 100% reliable in high humidity/ water spray areas?
Read More

Topics: Inductive Sensors, Ultrasonic Sensors, AS-Interface, Photoelectric Sensors, Ask an Expert

Ask an Expert Industrial Sensors - Episode 11

Posted by John Appleson on Thu, Jul 23, 2015

This episode of Ask an Expert for industrial sensors examines and provides answers to interesting sensing questions we've received from customers just like you. We explore and answer these questions:

  1. How do I get a narrower sound cone on an F260 series ultrasonic sensor?
  2. Is AS-Interface "data decoupling" the same as "filter integrated"?
  3. Can I use a diffuse mode photoelectric sensor to detect marks on a steel rivet?
  4. What is the output stage used for on an inductive sensor?
Read More

Topics: Inductive Sensors, Ultrasonic Sensors, AS-Interface, Photoelectric Sensors, Ask an Expert

Ask an Expert Industrial Sensors - Episode 10

Posted by John Appleson on Fri, Jun 19, 2015

This episode of Ask an Expert for industrial sensors examines and provides answers to interesting sensing questions we've received from customers just like you. We explore and answer these questions:

  1. What lengths of WCS absolute linear encoder system rails are available, and how do they connect?
  2. We are designing a cargo door locking system that has to be tamperproof. Would RFID technology work for this application?
  3. I was planning to use photoelectric sensors for people detection in a specific area. Which photoeye should I use?
  4. How do the wires connect in cable connector 42308C?
  5. How do I incorporate an AS-Interface network into an Allen-Bradley PLC?
Read More

Topics: AS-Interface, Photoelectric Sensors, Ask an Expert, RFID, Positioning Systems

Ask an Expert Industrial Sensors - Episode 9

Posted by John Appleson on Wed, May 13, 2015

This episode of Ask an Expert for industrial sensors examines and provides answers to interesting sensing questions we've received from customers just like you. We explore and answer these questions:

  1. Is extended addressing necessary when creating two separate ASI interface circuits on one AS-Interface gateway?
  2. What do the wire colors mean, and what is their function, on the ML8 series photoelectric sensor?
  3. How do you troubleshoot the beam width and sensing range of a UB4000-30GM series ultrasonic sensor?
  4. What kind of sensor is best to measure the density and color differentiation of a marking within a medium?
Read More

Topics: Ultrasonic Sensors, AS-Interface, Photoelectric Sensors, Ask an Expert

Ask an Expert Industrial Sensors - Episode 8

Posted by John Appleson on Wed, Apr 15, 2015

This episode of Ask an Expert for industrial sensors examines and provides answers to interesting sensing questions we've received from customers just like you. We explore and answer these questions:

1. Magnetic sensor MB60-12GM50-E2: What is the performance of this sensor like if the sensing surface is less than 10 mm away from the sensor?

2. How does the magnetic field sensor 41FY1 work? Is it a two-part magnetic sensor?

3. What is the required target size for the inductive sensor NJ5-18GM-N-5M? Will a 1/8 in. wide keyway that is .03 in. deep on a 4 in. diameter shaft work?

4. I'm trying to connect an NBB5-12GM50-E0-V1 inductive sensor to a PLC, but I am unable to make the two work together correctly!

5. Do you have cable connectors? What about for specialty cable types?
Read More

Topics: Inductive Sensors, Cables/ Cordsets, Ask an Expert, Magnetic Sensors

Ask an Expert Industrial Sensors - Episode 7

Posted by John Appleson on Thu, Feb 05, 2015

This episode of Ask an Expert for industrial sensors examines and provides answers to interesting sensing questions we've received from customers just like you. We explore and answer these questions:

1. I want to use a NBB1.5-8GM50-A2-V1 in a safety-related circuit. This circuit will overlap a safety light curtain. I want to use this sensor to monitor the safe position of a pneumatic slice when the light curtain is broken during the loading of a part. The prox signals will be monitored twice per cycle to ensure proper diagnostic coverage. Is it possible to wire two or more of these inductive sensors in a series if I need to monitor the position of more than one device?

2. Does Pepperl+Fuchs have a proximity sensor with a variable output where the output increases as the target cam moves away or toward the target area? The housing has a limitation of 10 mm x 8 cm with a sensing range of 1/16 in. to 1/4 in.

3. An NJ1.5-8GM-N sensor is used in a robot wrist tool changer. The tool is in a harsh environment. The cable is covered with a solvent-proof tube. Is this sensor available with a more durable jacket than PVC? Perhaps a jacket made from nylon impregnated polyurethane?

4. I am wondering what the sensing "cone" angle is on the ultrasonic sensor UB250-F12-U-V15. I have an application that needs to sense levels of liquid in a pan. The sensor would have to be placed close to the wall of the pan. How far away would the sensor need to be from the wall for a given sensing depth?

Read More

Topics: Inductive Sensors, Ultrasonic Sensors, Ask an Expert

Ask an Expert! Purge Systems - Episode 3

Posted by Kristen Barbour on Thu, Dec 18, 2014

Need help with an industrial purge system or purged enclosure? Ask an Expert! In this episode, Product Manager Brent Dean answers these questions:

  1. For an ATEX installation using purging, can I use a purge system with a standard IP6X enclosure?
  2. Will I need to have a notified body evaluate the final purge system and enclosure even though your purge system carries the ATEX certification?
  3. I have one of your Type Y purge systems and have a request to install an operator interface in a Class I, Div. 1 location. The operator interface is rated Class I, Div. 2. If I use a Y purge unit, will it be considered applicable for the area, or will there be an issue if the display protrudes through the enclosure?
  4. Can a 6000 series Type X purge system be used in a Class I, Div. 2 environment?
Read More

Topics: Purge/ Pressurization Systems, Ask an Expert

Ask an Expert Industrial Sensors - Episode 6

Posted by John Appleson on Wed, Nov 19, 2014

This episode of Ask an Expert for industrial sensors examines and provides answers to interesting sensing questions we've received from customers just like you. We explore and answer these questions:

1. I'm looking for an ultrasonic distance sensor to beam a signal to the top of a heavy steel column on an elevator (6 meters height). The column base might have some slack jerk. Can fog, gas, vapor, or loud noises affect the ultrasonic sensor?

2. I need updated software to program UC3000 ultrasonic sensors. Is there an update that will allow us to set up these sensors in a Windows 7 program?

3. I would like an ultrasonic sensor that can reliably detect falling objects in a harsh environment (mining operation). We are trying to set off an alarm when there is rock-fall.

4. I have an RFID controller IC-KP-B17-AIDA1 with 4 read heads. We are hooking them up to a 24 VDC power supply and need to know what size/type of fuse to put on the incoming side?

Read More

Topics: Ultrasonic Sensors, Ask an Expert, RFID

Subscribe to Email Updates

Search our blog!

Loading Google Custom Search.....

Follow Me